Haier · Outdoor unit · Heat recovery
Haier MRV 5-RC
Haier MRV 5-RC. Heat recovery: cools and heats at the same time, in different zones. Up to 22 HP from one module.


Outdoor unit · Heat recovery
2 or 3 pipes
MRV 5-RC is Haier's heat recovery VRF outdoor unit: it cools some zones and heats others at the same time, with full DC inverter. Haier offers it with 2 or 3 pipes; the spec sheet below is for the 3-pipe version.
One module runs from 8 to 22 HP (22.4 to 60 kW); up to 4 modules combine for up to 88 HP (240 kW), with up to 64 indoor units and up to 1,000 m of piping in total. The table shows the single modules; you will find the combinations in Haier's catalogue.
- Cooling capacity
- 22.40 to 60.00 kW
- Heating capacity
- 22.40 to 60.00 kW
- Indoor units
- up to 36
Built-in Modbus
Features
Cooling and heating at once
Heat recovery moves heat from the zones being cooled to the zones being heated.
From 8 to 88 HP
One module up to 22 HP, four modules up to 88 HP.
Piping up to 1,000 m
Long pipe runs, for large buildings and more freedom in installation.
110 Pa static pressure
The fan works with up to 110 Pa static pressure, even with a discharge duct.
Flexible installation
Thanks to its design, the unit can be installed in many ways and in different spaces.
Built-in Modbus
The MODBUS RTU protocol is inside the unit, which connects directly to a BMS with no extra gateway.
Smart Link (optional)
A wireless link between indoor and outdoor units, in place of the communication cable.
Technical data
| Model | AV08IMVURA | AV10IMVURA | AV12IMVURA | AV14IMVURA | AV16IMVURA | AV18IMVURA | AV20IMVURA | AV22IMVURA |
|---|---|---|---|---|---|---|---|---|
| Capacity, HP | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 |
| Electrical supply | 3N~ 380–400 V | 3N~ 380–400 V | 3N~ 380–400 V | 3N~ 380–400 V | 3N~ 380–400 V | 3N~ 380–400 V | 3N~ 380–400 V | 3N~ 380–400 V |
| Capacity and efficiency | ||||||||
| Cooling capacity, kW | 22.40 | 28.00 | 33.50 | 40.00 | 45.00 | 50.00 | 56.00 | 60.00 |
| Heating capacity, kW | 22.40 | 28.00 | 33.50 | 40.00 | 45.00 | 50.00 | 56.00 | 60.00 |
| EER (cooling), W/W | 3.84 | 3.65 | 3.37 | 3.25 | 3.23 | 3.10 | 2.76 | 2.70 |
| COP (heating), W/W | 4.16 | 4.20 | 3.82 | 3.80 | 3.95 | 3.65 | 3.55 | 3.35 |
| SEER (cooling), W/W | 6.12 | 6.68 | 6.46 | 6.37 | 6.86 | 6.48 | 5.78 | 5.63 |
| SCOP (heating, average climate), W/W | 3.82 | 3.94 | 3.99 | 3.77 | 4.21 | 3.99 | 3.93 | 3.50 |
| Max. indoor units | 13 | 16 | 20 | 24 | 27 | 30 | 33 | 36 |
| Indoor / outdoor capacity ratio, % | 50–130 | 50–130 | 50–130 | 50–130 | 50–130 | 50–130 | 50–130 | 50–130 |
| Airflow, m³/h | 12000 | 12000 | 13500 | 13500 | 17000 | 17000 | 19000 | 19000 |
| Fan static pressure, Pa | 110 | 110 | 110 | 110 | 110 | 110 | 110 | 110 |
| Sound | ||||||||
| Outdoor unit, dB(A) | 57 | 58 | 60 | 61 | 62 | 63 | 63 | 64 |
| Outdoor unit sound power, dB(A) | 81 | 82 | 88 | 88 | 88 | 88 | 88 | 90 |
| Dimensions and weight | ||||||||
| Outdoor unit, mm (W × D × H) | 980 × 750 × 1690 | 980 × 750 × 1690 | 980 × 750 × 1690 | 980 × 750 × 1690 | 1410 × 750 × 1690 | 1410 × 750 × 1690 | 1410 × 750 × 1690 | 1410 × 750 × 1690 |
| Outdoor unit weight, kg | 246 | 246 | 257 | 257 | 366 | 366 | 375 | 375 |
| Installation and operation | ||||||||
| Compressor | 1 × DC inverter scroll | 1 × DC inverter scroll | 1 × DC inverter scroll | 1 × DC inverter scroll | 2 × DC inverter scroll | 2 × DC inverter scroll | 2 × DC inverter scroll | 2 × DC inverter scroll |
| Pipes, liquid / suction gas / high pressure gas, mm | 9.52 / 19.05 / 19.05 | 9.52 / 22.22 / 19.05 | 12.70 / 25.40 / 22.22 | 12.70 / 25.40 / 22.22 | 12.70 / 28.58 / 25.40 | 15.88 / 28.58 / 25.40 | 15.88 / 28.58 / 25.40 | 15.88 / 28.58 / 25.40 |
| Max. total pipe length, m | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 |
| Longest pipe run, m (equivalent / actual) | 260 / 220 | 260 / 220 | 260 / 220 | 260 / 220 | 260 / 220 | 260 / 220 | 260 / 220 | 260 / 220 |
| Max. height difference, m (outdoor unit below / above) | 110 / 90 | 110 / 90 | 110 / 90 | 110 / 90 | 110 / 90 | 110 / 90 | 110 / 90 | 110 / 90 |
| Max. height difference between indoor units, m | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
| Outdoor temperature range, cooling, °C | −5 to 50 | −5 to 50 | −5 to 50 | −5 to 50 | −5 to 50 | −5 to 50 | −5 to 50 | −5 to 50 |
| Outdoor temperature range, heating, °C | −23 to 21 | −23 to 21 | −23 to 21 | −23 to 21 | −23 to 21 | −23 to 21 | −23 to 21 | −23 to 21 |
| Refrigerant | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A |
| Factory refrigerant charge, kg | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Product documentation
Specifications refer to the published series. We confirm the configuration, accessories and data for the proposed model in the quotation.
Selection and quotation
Comfort Clima helps identify the appropriate version and accessories for this product. Send us floor plans, room loads, unit locations, piping lengths and BMS requirements.
More in this category
Planning an order or project?
Send your equipment list, quantities and required date. We can help with selection and prepare a quotation for your requirements.
Contact
Tell us what you need
Whether you need one unit or equipment for an entire project, send your requirements with models, quantities and location. We will respond with a quotation and availability information.
- Call us
- +383 48 77 22 88
- Email us
- info@comfort-clima.com
- Find us
- Rruga Ukë Mavriqi 23, Shkabaj
Prishtina 10000, Kosovo - Hours
- Monday to Friday, 08:00–17:00
Your enquiry is ready to email
Complete the submission in your email application. If it did not open, call +383 48 77 22 88 or email info@comfort-clima.com.