Haier · Outdoor unit
Haier MRV S II
Haier MRV S II. A compact unit for tight spaces, with a DC twin rotary compressor, low noise and self-cleaning.


Outdoor unit
Front discharge
MRV S II is Haier's front discharge VRF outdoor unit, compact, for tight spaces. It has a DC inverter rotary or twin rotary compressor, a large fan and a high efficiency condenser.
Sizes from 4 to 12 HP (12.1 to 31.5 kW) in a single module, single-phase or three-phase. It connects up to 19 indoor units, with up to 300 m of piping in total. It has built-in Modbus, self-cleaning and low noise with automatic sound reduction.
- Cooling capacity
- 12.10 to 31.50 kW
- Heating capacity
- 12.10 to 31.50 kW
- Indoor units
- up to 19
Features
From 4 to 12 HP
One single module covers 12.1 to 31.5 kW.
Piping up to 300 m
Long pipe runs, for more freedom in installation.
Compact design
The front discharge unit takes little space and fits into tight areas.
30 Pa static pressure
The fan works with a static pressure of up to 30 Pa.
Built-in Modbus
The MODBUS RTU protocol is inside the unit, which connects directly to a BMS with no extra gateway.
Silence
The fan, air ducts and motor are designed for low noise, with automatic sound reduction.
Self Clean
The unit freezes the evaporator surface with moisture from the air and removes the dirt as the ice thaws.
Technical data
| Model | AU042FNERA | AU052FNERA | AU042FPERA | AU052FPERA | AU062FPERA | AU04IFPERA | AU05IFPERA | AU06IFPERA | AU08NFKERA | AU10NFKERA | AU12NFKERA |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Capacity, HP | 4 | 5 | 4 | 5 | 6 | 4 | 5 | 6 | 8 | 10 | 12 |
| Electrical supply | 1~ 220–240 V | 1~ 220–240 V | 1~ 220–240 V | 1~ 220–240 V | 1~ 220–240 V | 3~ 380–415 V | 3~ 380–415 V | 3~ 380–415 V | 3~ 380–415 V | 3~ 380–415 V | 3~ 380–415 V |
| Capacity and efficiency | |||||||||||
| Cooling capacity, kW | 12.10 | 14.00 | 12.10 | 14.00 | 15.50 | 12.10 | 14.00 | 15.50 | 22.60 | 28.00 | 31.50 |
| Heating capacity, kW | 12.10 | 14.00 | 12.10 | 14.00 | 15.50 | 12.10 | 14.00 | 15.50 | 22.60 | 30.50 | 31.50 |
| EER (cooling), W/W | 2.85 | 2.80 | 3.35 | 3.23 | 3.00 | 3.35 | 3.23 | 3.00 | 3.25 | 3.23 | 2.73 |
| COP (heating), W/W | 2.95 | 2.90 | 3.75 | 3.72 | 3.10 | 3.75 | 3.72 | 3.10 | 3.90 | 3.80 | 3.71 |
| SEER (cooling), W/W | 4.90 | 4.85 | 6.82 | 6.65 | 6.80 | 6.82 | 6.65 | 6.80 | 7.67 | 7.65 | 7.47 |
| SCOP (heating, average climate), W/W | 3.50 | 3.55 | 4.05 | 4.11 | 4.05 | 4.05 | 4.11 | 4.05 | 4.05 | 4.16 | 4.21 |
| Max. indoor units | 7 | 8 | 8 | 10 | 13 | 8 | 10 | 13 | 13 | 16 | 19 |
| Indoor / outdoor capacity ratio, % | 50–130 | 50–130 | 50–130 | 50–130 | 50–130 | 50–130 | 50–130 | 50–130 | 50–130 | 50–130 | 50–130 |
| Airflow, m³/h | 5400 | 5400 | 7200 | 7200 | 7200 | 7200 | 7200 | 7200 | 10000 | 10000 | 10000 |
| Sound | |||||||||||
| Outdoor unit, cooling, dB(A) | 58 | 60 | 57 | 58 | 59 | 57 | 58 | 59 | 63 | 64 | 65 |
| Outdoor unit, heating, dB(A) | 60 | 62 | 57 | 58 | 59 | 57 | 58 | 59 | 65 | 66 | 67 |
| Dimensions and weight | |||||||||||
| Outdoor unit, mm (W × D × H) | 950 × 370 × 965 | 950 × 370 × 965 | 950 × 370 × 1350 | 950 × 370 × 1350 | 950 × 370 × 1350 | 950 × 370 × 1350 | 950 × 370 × 1350 | 950 × 370 × 1350 | 1050 × 400 × 1636 | 1050 × 400 × 1636 | 1050 × 400 × 1636 |
| Outdoor unit weight, kg | 90 | 90 | 108 | 108 | 108 | 108 | 108 | 108 | 149 | 149 | 149 |
| Installation and operation | |||||||||||
| Compressor | Rotary inverter | Rotary inverter | Rotary inverter | Rotary inverter | Rotary inverter | Rotary inverter | Rotary inverter | Rotary inverter | Twin rotary inverter | Twin rotary inverter | Twin rotary inverter |
| Pipes, liquid / gas, mm | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 19.05 | 9.52 / 22.22 | 12.7 / 25.40 |
| Max. total pipe length, m | 120 | 120 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 |
| Longest pipe run, m (equivalent / actual) | 70 / 60 | 70 / 60 | 175 / 150 | 175 / 150 | 175 / 150 | 175 / 150 | 175 / 150 | 175 / 150 | 175 / 150 | 175 / 150 | 175 / 150 |
| Height difference between outdoor and indoor units, m | 30 / 20 | 30 / 20 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Max. height difference between indoor units, m | 10 | 10 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
| Outdoor temperature range, cooling, °C | −5 to 50 | −5 to 50 | −5 to 50 | −5 to 50 | −5 to 50 | −5 to 50 | −5 to 50 | −5 to 50 | −5 to 48 | −5 to 48 | −5 to 48 |
| Outdoor temperature range, heating, °C | −15 to 21 | −15 to 21 | −20 to 27 | −20 to 27 | −20 to 27 | −20 to 27 | −20 to 27 | −20 to 27 | −20 to 27 | −20 to 27 | −20 to 27 |
| Refrigerant | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A |
| Factory refrigerant charge, kg | 3.30 | 3.30 | 4.00 | 4.00 | 4.00 | 4.00 | 4.00 | 4.00 | 5.10 | 5.10 | 5.10 |
Product documentation
Specifications refer to the published series. We confirm the configuration, accessories and data for the proposed model in the quotation.
Selection and quotation
Comfort Clima helps identify the appropriate version and accessories for this product. Send us floor plans, room loads, unit locations, piping lengths and BMS requirements.
More in this category
Planning an order or project?
Send your equipment list, quantities and required date. We can help with selection and prepare a quotation for your requirements.
Contact
Tell us what you need
Whether you need one unit or equipment for an entire project, send your requirements with models, quantities and location. We will respond with a quotation and availability information.
- Call us
- +383 48 77 22 88
- Email us
- info@comfort-clima.com
- Find us
- Rruga Ukë Mavriqi 23, Shkabaj
Prishtina 10000, Kosovo - Hours
- Monday to Friday, 08:00–17:00
Your enquiry is ready to email
Complete the submission in your email application. If it did not open, call +383 48 77 22 88 or email info@comfort-clima.com.