Fujitsu · Ducted

High static pressure duct

For long ducts and large spaces, up to 22 kW. Quiet, with automatic airflow adjustment.

Fujitsu KHTAP high static pressure duct unitFujitsu

Ducted

KHTAP · KHTB · KHTA

Fujitsu's high static pressure ducts are for long duct runs and large spaces. There are three series: KHTAP (compact, up to 200 Pa), KHTB (up to 250 Pa) and KHTA (high efficiency, up to 260 Pa).

Sizes from 3.5 to 22 kW. The unit sets the airflow the installation needs by itself. KHTAP 9.5 to 13.4 kW and KHTB also come three-phase 400 V; KHTA 15 to 22 kW are three-phase.

Capacity
3.5 to 22 kW
Power supply
Single or three phase
Pressure
up to 200 Pa

3.5 · 4.3 · 5.2 · 6.0 · 6.8 · 8.5 · 9.5 · 12.1 · 13.4 · 15 · 19 · 22 kW

Features

  • Efficient and quiet

    A V-shaped heat exchanger, an air stabiliser and a high-efficiency DC fan motor keep the unit efficient and quiet.

  • Small, light outdoor unit

    The outdoor unit is more compact and lighter, so it fits tight spaces.

  • Automatic airflow adjustment

    The unit works out the airflow the installation needs and sets it by itself.

  • KHTA: splits in two

    The indoor unit separates into a fan section and a heat exchanger section to pass through a ventilation opening, and it has a carrying handle.

  • Central control (option)

    With optional MODBUS or KNX interfaces, the air conditioning is controlled together with the building's other systems.

Technical data

The highlighted rows matter most: how much the unit cools, how much it heats and how much electricity it saves.

Indoor unitARXG12KHTAPARXG14KHTAPARXG18KHTAPARXG22KHTAPARXG24KHTAPARXG30KHTAPARXG36KHTAPARXG45KHTAPARXG54KHTAPARXG45KHTBARXG54KHTBARXH60KHTAARXH72KHTAARXH90KHTA
Outdoor unitAOEG12KBTBAOEG14KBTBAOEG18KBTBAOEG22KBTBAOEG24KBTBAOEG30KBTBAOEG36KBTBAOEG45KBTBAOEG54KBTBAOEG45KBTBAOEG54KBTBAOEH60KRTAAOEH72KRTAAOEH90KRTA
Power supply1~ 230 V1~ 230 V1~ 230 V1~ 230 V1~ 230 V1~ 230 V1~ 230 V1~ 230 V1~ 230 V1~ 230 V1~ 230 V3N~ 400 V3N~ 400 V3N~ 400 V
Capacity and efficiency Most important
Cooling capacity, kW (rated, min–max)How much it cools. The more kW, the bigger the room it can cool.3.5 (0.9–4.4)4.3 (0.9–5.4)5.2 (0.9–5.9)6.0 (0.9–6.7)6.8 (0.9–8.0)8.5 (2.8–10.0)9.5 (2.8–11.2)12.1 (4.0–14.0)13.4 (4.5–14.5)12.1 (4.0–14.0)13.4 (5.0–14.5)15.0 (5.0–17.5)19.0 (6.0–22.0)22.0 (6.5–24.2)
Heating capacity, kW (rated, min–max)How much it heats. In brackets: the lowest and highest output it reaches.4.1 (0.9–5.7)5.0 (0.9–6.5)6.0 (0.9–7.5)7.0 (0.9–8.0)7.5 (0.9–9.1)10.0 (2.7–11.2)10.8 (2.7–12.7)13.5 (4.2–16.2)15.5 (4.7–16.5)13.5 (5.0–16.2)15.5 (5.5–18.0)18.0 (5.1–22.4)22.4 (6.0–25.0)25.0 (6.5–26.0)
SEER (cooling), W/WHow much it saves when cooling through the summer. The higher, the less electricity it uses.6.306.206.506.506.506.206.10–––––––
SCOP (heating, average climate), W/WHow much it saves when heating through the winter. The higher, the less electricity it uses.4.104.004.104.204.104.004.20–––––––
Energy class, coolingThe class on the energy label. A+++ is the best.A++A++A++A++A++A++A++–––––––
Energy class, heatingThe class on the energy label. A+++ is the best.A+A+A+A+A+A+A+–––––––
External static pressure, Pa (in brackets: standard)30–200 (35)30–200 (35)30–200 (35)30–200 (35)30–200 (35)30–200 (47)30–200 (47)30–200 (60)30–200 (60)100–250 (100)100–250 (100)60–260 (60)60–200 (72)60–200 (72)
Sound
Indoor unit, dB(A) (high / quiet)32 / 2433 / 2528 / 2028 / 2032 / 2136 / 2936 / 2639 / 2939 / 2947 / 4047 / 4045 / 3643 / 3544 / 37
Outdoor unit, dB(A)4749505153535557575757536161
Dimensions and weight
Indoor unit, mm (H × W × D)300 × 700 × 700300 × 700 × 700300 × 1000 × 700300 × 1000 × 700300 × 1000 × 700300 × 1000 × 700300 × 1400 × 700300 × 1400 × 700300 × 1400 × 700400 × 1050 × 500400 × 1050 × 500425 × 1250 × 490360 × 1400 × 850360 × 1400 × 850
Outdoor unit, mm (H × W × D)542 × 799 × 290542 × 799 × 290632 × 799 × 290632 × 799 × 290716 × 820 × 315788 × 940 × 320788 × 940 × 320998 × 940 × 320998 × 940 × 320998 × 940 × 320998 × 940 × 3201418 × 970 × 3701418 × 970 × 3701418 × 970 × 370
Indoor unit weight, kg27.027.035.035.036.036.046.046.046.046.046.052.069.069.0
Outdoor unit weight, kg33.033.036.038.042.052.052.067.067.067.067.095.0103.0103.0
Installation and operation
Max. pipe length, m (in brackets: no extra charge)25 (15)25 (15)30 (20)30 (20)30 (20)50 (30)50 (30)50 (30)50 (30)50 (30)50 (30)75 (30)100 (40)100 (40)
Max. height difference, m2020202525303030303030303030
Outdoor temperature range, cooling, °C−15 to 46−15 to 46−15 to 46−15 to 46−15 to 46−15 to 46−15 to 46−15 to 46−15 to 46−15 to 46−15 to 46−15 to 50−15 to 50−15 to 50
Outdoor temperature range, heating, °C−15 to 24−15 to 24−15 to 24−15 to 24−15 to 24−15 to 24−15 to 24−15 to 24−15 to 24−15 to 24−15 to 24−20 to 24−20 to 24−20 to 24
RefrigerantR32R32R32R32R32R32R32R32R32R32R32R32R32R32
Refrigerant charge, g850850102012501250190019002700270027002700340040004000

Values from the official Fujitsu General page for this series (product page). They may vary by version; we confirm them in the quote.

Installer, reseller or project?

Ask for wholesale prices and availability. We also help with technical selection and the equipment list.

Contact

Request a quote.

Installer, reseller, project or home: tell us what you need and we will reply with pricing and availability.

Find us
Rruga Ukë Mavriqi 23, Shkabaj
Prishtina 10000, Republic of Kosovo
Hours
Monday to Friday, 08:00 to 17:00

Your request

The button opens your email app with the request written out. You just press Send.