Haier · Outdoor unit · R32

Haier MRV7S

Haier MRV7S. The new R32 system, with a leak detector in every indoor unit and an alarm on the controller. Piping up to 300 m, or 400 m with two fans.

Haier MRV7SHaier

Outdoor unit · R32

4 · 5 · 6 HP single fan · 8 · 10 · 12 HP double fan

MRV7S is Haier's new R32 VRF system with front discharge: 4, 5 and 6 HP with one fan (single-phase or three-phase), 8, 10 and 12 HP with two fans (three-phase).

Every R32 indoor unit has a built-in leak detector, and the controllers give a sound and light alarm. The 4 to 6 HP units have built-in R32 shut-off valves; for 8 to 12 HP there is the optional SVP160A box. Piping goes up to 300 m (single fan) or 400 m (double fan), and the new indoor units also work with R410A.

Cooling capacity
12.10 to 31.50 kW
Heating capacity
12.10 to 31.50 kW
Indoor units
up to 30

Front air discharge

Features

  • Diamond Shield R32 safety

    Leak detectors in the indoor units that need no replacement after detection, a sound and light alarm, and software that calculates the amount of refrigerant in the room.

  • Shut-off valves

    On 4 to 6 HP they are built into the unit; on 8 to 12 HP the SVP160A box is added, with a battery that closes the valves even in a power cut.

  • Refrigerant recovery

    If there is a leak, the system can pump the R32 back to the outdoor unit and isolate it (single fan units), while the other units keep running.

  • PID 0.5°C control

    The operating frequency is optimised before the set temperature is reached, then adjusted constantly so the temperature stays precise.

  • Piping up to 300 m / 400 m

    300 m in total with a single fan, 400 m with two fans.

  • Automatic addressing

    Each indoor unit gets its address by itself, which speeds up commissioning on large systems.

  • R32 / R410A indoor units

    The new R32 indoor units also work with R410A.

Technical data

ModelAU042FCFRAAU052FCFRAAU062FCFRAAU04IFCFRAAU05IFCFRAAU06IFCFRAAU08NFAFRAAU10NFAFRAAU12NFAFRA
Capacity, HP45645681012
Electrical supply1~ 220–240 V1~ 220–240 V1~ 220–240 V3~ 380–415 V3~ 380–415 V3~ 380–415 V3~ 380–415 V3~ 380–415 V3~ 380–415 V
Capacity and efficiency
Cooling capacity, kW12.1014.0015.5012.1014.0015.5022.6028.0031.50
Heating capacity, kW12.1014.0015.5012.1014.0015.5022.6028.0031.50
EER (cooling), W/W3.523.403.233.523.403.233.253.232.73
COP (heating), W/W4.454.003.804.454.003.803.903.803.71
SEER (cooling), W/W8.097.857.628.097.857.627.677.657.50
SCOP (heating, average climate), W/W4.884.754.714.884.754.714.654.604.55
Max. indoor units131618131618202530
Indoor / outdoor capacity ratio, %50–15050–15050–15050–15050–15050–15050–15050–15050–150
Airflow, m³/h580058005800580058005800125001250012500
Max. external static pressure, Pa353535353535454545
Sound
Outdoor unit, cooling, dB(A)545556545556575961
Outdoor unit, heating, dB(A)565758565758606264
Dimensions and weight
Outdoor unit, mm (W × D × H)1050 × 400 × 8401050 × 400 × 8401050 × 400 × 8401050 × 400 × 8401050 × 400 × 8401050 × 400 × 8401050 × 400 × 16351050 × 400 × 16351050 × 400 × 1635
Outdoor unit weight, kg969696106106106165.5165.5165.5
Installation and operation
CompressorInverter twin rotaryInverter twin rotaryInverter twin rotaryInverter twin rotaryInverter twin rotaryInverter twin rotaryInverter twin rotaryInverter twin rotaryInverter twin rotary
Pipes, liquid / gas, mm9.52 / 19.059.52 / 19.059.52 / 19.059.52 / 19.059.52 / 19.059.52 / 19.0512.70 / 19.0512.70 / 19.0512.70 / 19.05
Max. total pipe length, m300300300300300300400400400
Longest pipe run, m120120120120120120150150150
Height difference between outdoor and indoor units, m50 / 4050 / 4050 / 4050 / 4050 / 4050 / 4050 / 4050 / 4050 / 40
Max. height difference between indoor units, m151515151515151515
Outdoor temperature range, cooling, °C−5 to 52−5 to 52−5 to 52−5 to 52−5 to 52−5 to 52−5 to 52−5 to 52−5 to 52
Outdoor temperature range, heating, °C−25 to 21−25 to 21−25 to 21−25 to 21−25 to 21−25 to 21−25 to 21−25 to 21−25 to 21
RefrigerantR32R32R32R32R32R32R32R32R32
Factory refrigerant charge, kg3.003.003.003.003.003.006.506.506.50

Product documentation

Specifications refer to the published series. We confirm the configuration, accessories and data for the proposed model in the quotation.

Selection and quotation

Comfort Clima helps identify the appropriate version and accessories for this product. Send us floor plans, room loads, unit locations, piping lengths and BMS requirements.

Planning an order or project?

Send your equipment list, quantities and required date. We can help with selection and prepare a quotation for your requirements.

Contact

Tell us what you need

Whether you need one unit or equipment for an entire project, send your requirements with models, quantities and location. We will respond with a quotation and availability information.

Find us
Rruga Ukë Mavriqi 23, Shkabaj
Prishtina 10000, Kosovo
Hours
Monday to Friday, 08:00–17:00

Your request

Your email application will open with a prepared enquiry. Select Send in that application to submit it.