MRV7S is Haier's new R32 VRF system with front discharge: 4, 5 and 6 HP with one fan (single-phase or three-phase), 8, 10 and 12 HP with two fans (three-phase).
Every R32 indoor unit has a built-in leak detector, and the controllers give a sound and light alarm. The 4 to 6 HP units have built-in R32 shut-off valves; for 8 to 12 HP there is the optional SVP160A box. Piping goes up to 300 m (single fan) or 400 m (double fan), and the new indoor units also work with R410A.
- Cooling capacity
- 12.10 to 31.50 kW
- Heating capacity
- 12.10 to 31.50 kW
- Indoor units
- up to 30
Front air discharge
Features
Diamond Shield R32 safety
Leak detectors in the indoor units that need no replacement after detection, a sound and light alarm, and software that calculates the amount of refrigerant in the room.
Shut-off valves
On 4 to 6 HP they are built into the unit; on 8 to 12 HP the SVP160A box is added, with a battery that closes the valves even in a power cut.
Refrigerant recovery
If there is a leak, the system can pump the R32 back to the outdoor unit and isolate it (single fan units), while the other units keep running.
PID 0.5°C control
The operating frequency is optimised before the set temperature is reached, then adjusted constantly so the temperature stays precise.
Piping up to 300 m / 400 m
300 m in total with a single fan, 400 m with two fans.
Automatic addressing
Each indoor unit gets its address by itself, which speeds up commissioning on large systems.
R32 / R410A indoor units
The new R32 indoor units also work with R410A.
Technical data
| Model | AU042FCFRA | AU052FCFRA | AU062FCFRA | AU04IFCFRA | AU05IFCFRA | AU06IFCFRA | AU08NFAFRA | AU10NFAFRA | AU12NFAFRA |
|---|---|---|---|---|---|---|---|---|---|
| Capacity, HP | 4 | 5 | 6 | 4 | 5 | 6 | 8 | 10 | 12 |
| Electrical supply | 1~ 220–240 V | 1~ 220–240 V | 1~ 220–240 V | 3~ 380–415 V | 3~ 380–415 V | 3~ 380–415 V | 3~ 380–415 V | 3~ 380–415 V | 3~ 380–415 V |
| Capacity and efficiency | |||||||||
| Cooling capacity, kW | 12.10 | 14.00 | 15.50 | 12.10 | 14.00 | 15.50 | 22.60 | 28.00 | 31.50 |
| Heating capacity, kW | 12.10 | 14.00 | 15.50 | 12.10 | 14.00 | 15.50 | 22.60 | 28.00 | 31.50 |
| EER (cooling), W/W | 3.52 | 3.40 | 3.23 | 3.52 | 3.40 | 3.23 | 3.25 | 3.23 | 2.73 |
| COP (heating), W/W | 4.45 | 4.00 | 3.80 | 4.45 | 4.00 | 3.80 | 3.90 | 3.80 | 3.71 |
| SEER (cooling), W/W | 8.09 | 7.85 | 7.62 | 8.09 | 7.85 | 7.62 | 7.67 | 7.65 | 7.50 |
| SCOP (heating, average climate), W/W | 4.88 | 4.75 | 4.71 | 4.88 | 4.75 | 4.71 | 4.65 | 4.60 | 4.55 |
| Max. indoor units | 13 | 16 | 18 | 13 | 16 | 18 | 20 | 25 | 30 |
| Indoor / outdoor capacity ratio, % | 50–150 | 50–150 | 50–150 | 50–150 | 50–150 | 50–150 | 50–150 | 50–150 | 50–150 |
| Airflow, m³/h | 5800 | 5800 | 5800 | 5800 | 5800 | 5800 | 12500 | 12500 | 12500 |
| Max. external static pressure, Pa | 35 | 35 | 35 | 35 | 35 | 35 | 45 | 45 | 45 |
| Sound | |||||||||
| Outdoor unit, cooling, dB(A) | 54 | 55 | 56 | 54 | 55 | 56 | 57 | 59 | 61 |
| Outdoor unit, heating, dB(A) | 56 | 57 | 58 | 56 | 57 | 58 | 60 | 62 | 64 |
| Dimensions and weight | |||||||||
| Outdoor unit, mm (W × D × H) | 1050 × 400 × 840 | 1050 × 400 × 840 | 1050 × 400 × 840 | 1050 × 400 × 840 | 1050 × 400 × 840 | 1050 × 400 × 840 | 1050 × 400 × 1635 | 1050 × 400 × 1635 | 1050 × 400 × 1635 |
| Outdoor unit weight, kg | 96 | 96 | 96 | 106 | 106 | 106 | 165.5 | 165.5 | 165.5 |
| Installation and operation | |||||||||
| Compressor | Inverter twin rotary | Inverter twin rotary | Inverter twin rotary | Inverter twin rotary | Inverter twin rotary | Inverter twin rotary | Inverter twin rotary | Inverter twin rotary | Inverter twin rotary |
| Pipes, liquid / gas, mm | 9.52 / 19.05 | 9.52 / 19.05 | 9.52 / 19.05 | 9.52 / 19.05 | 9.52 / 19.05 | 9.52 / 19.05 | 12.70 / 19.05 | 12.70 / 19.05 | 12.70 / 19.05 |
| Max. total pipe length, m | 300 | 300 | 300 | 300 | 300 | 300 | 400 | 400 | 400 |
| Longest pipe run, m | 120 | 120 | 120 | 120 | 120 | 120 | 150 | 150 | 150 |
| Height difference between outdoor and indoor units, m | 50 / 40 | 50 / 40 | 50 / 40 | 50 / 40 | 50 / 40 | 50 / 40 | 50 / 40 | 50 / 40 | 50 / 40 |
| Max. height difference between indoor units, m | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
| Outdoor temperature range, cooling, °C | −5 to 52 | −5 to 52 | −5 to 52 | −5 to 52 | −5 to 52 | −5 to 52 | −5 to 52 | −5 to 52 | −5 to 52 |
| Outdoor temperature range, heating, °C | −25 to 21 | −25 to 21 | −25 to 21 | −25 to 21 | −25 to 21 | −25 to 21 | −25 to 21 | −25 to 21 | −25 to 21 |
| Refrigerant | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 |
| Factory refrigerant charge, kg | 3.00 | 3.00 | 3.00 | 3.00 | 3.00 | 3.00 | 6.50 | 6.50 | 6.50 |
Product documentation
Specifications refer to the published series. We confirm the configuration, accessories and data for the proposed model in the quotation.
Selection and quotation
Comfort Clima helps identify the appropriate version and accessories for this product. Send us floor plans, room loads, unit locations, piping lengths and BMS requirements.
More in this category
Planning an order or project?
Send your equipment list, quantities and required date. We can help with selection and prepare a quotation for your requirements.
Contact
Tell us what you need
Whether you need one unit or equipment for an entire project, send your requirements with models, quantities and location. We will respond with a quotation and availability information.
- Call us
- +383 48 77 22 88
- Email us
- info@comfort-clima.com
- Find us
- Rruga Ukë Mavriqi 23, Shkabaj
Prishtina 10000, Kosovo - Hours
- Monday to Friday, 08:00–17:00
Your enquiry is ready to email
Complete the submission in your email application. If it did not open, call +383 48 77 22 88 or email info@comfort-clima.com.